Screw-On Hauling Attachments
   
 
Screw-On Power Cable Hauling Eye
CLP’s screw-on power cable hauling eye is designed to offer maximum gripping strength on cable conductors of all types and sizes and suits all cable with an inner core. A short extension sleeve covers and protects the face of the cable insulation during hauling.
             
CLP Code Conductor Dia Inside Dia of Eye A Outside Dia of Head B Length Spike C Length of Head D Length of Nut E
CER-2025 20-25 24 60 70 95 50
CER-2530 25-30 24 60 70 95 50
CER-3035 30-35 24 70 82 125 80
CER-3540 35-40 29 70 100 125 80
CER-4045 40-45 29 82 116 190 90
CER-4550 45-50 29 89 116 215 95
CER-5055 50-55 29 100 135 215 95
Tolerance ± 1 ± 2 ± 3 ± 3 ± 1  
             
   
 
Procedures for Installing the Power Eye
   
1. Remove all insulation materials, including the sheathing on the sectors inside, for a length 40mm longer than the nut used. Slide the nut over the exposed conductors securing it about 20mm in front of the sheathing stack, with the grub screws in the rear shoulder of the nut.
2. Hammer the conical shaped pin into the mass of wires until it won't move any further. If the top of the pin is below the lip of the nut by more than 20mm then a larger pin should be used. (The pin will protrude past the end of the nut, this is normal.)

3. Screw the head onto the nut and secure it with the grub screws situated at the bottom of the head.

4. If the head has a sleeve attached, then this should be crimped down onto the outer sheath of the cable to seal the cable from water and dirt, or covered with a piece of heat shrink tubing.

 
Screw-On Fibre Optic Cable Hauling Eye
 
Fibre optic hauling eyes designed for securing the cable in one simple operation without affecting the fibres. No special tools are required, making these eyes easy to use in the field.
  • CLP Code
  • FOH-1965
  • FOC-25
  • FOC-30
  • FOC-35
  • FOC-40
  • FOS-12
  • FOS-18
  • FOS-23
  • FOG-00
  • FOP-00
  • Description
  • 19mm OD Head 6.5mm ID
  • Sleeve to suit CTM of 2.5mm
  • Sleeve to suit CTM of 3.0mm
  • Sleeve to suit CTM of 3.5mm
  • Sleeve to suit CTM of 4.0mm
  • Skirt to suit 8-11mm OD cable
  • Skirt to suit 11-17mm OD cable
  • Skirt to suit 17-22mm OD cable
  • Super gel Adhesive
  • Punch for removing FOC
  • CLP Code
  • FOH-KIT
  • Description
  • Reusable CS fibre eye hauling kit
  • Kit comprises
  • 1 x FPB-100 Plastic box
  • 1 x FOG-00 Super gel Adhesive
  • 1 x FOP-00 Punch
  • 1 x FOS-12 Skirt to suit 8-11mm OD cable
  • 1 x FOS-18 Skirt to suit 11-17mm OD cable
  • 1 x FOS-23 Skirt to suit 17-22mm OD cable
  • 3 x FOC-25 Sleeve to suit CTM of 2.5mm
  • 3 x FOC-30 Sleeve to suit CTM of 3.0mm
  • 1 x FOH-1965 19mm Head
  • 2 x Allen keys to suit.